24-7 Available
24-7 Available
Reusable laparoscopic instruments across the working diameters a minimal-access theatre actually stocks: 5mm and 10mm shafts in 33cm, 38cm and 45cm lengths, plus the trocars, cannulas and articulating retractors that go in around them.
The range runs from single-piece graspers through modular systems where insert, sheath and handle are ordered separately, and includes monopolar and bipolar patterns, FLEXLAP articulating instruments, and named systems from Wolf, Snowden-Pencer, Davis & Geck, Weck and Cabot Medical.
AED 33321AF-R Endo Clinch Grasper w/ Ratchet Handle Storz Style Diameter: 5mm Working length: 36cm 90 Days Limited Warranty
AED 33321DN Dolphin Nose Grasper Dissector Storz Style Diameter: 5mm Working length: 36cm 90 Days Limited Warranty
AED 33321DN-R Dolphin Nose Grasper Dissector w/ Ratchet Handle Storz Style Diameter: 5mm Working length: 36cm 90 Days Limited Warranty
AED 8517A Curved Left Grasper, 1mm 90 Days Limited Warranty
AED 33321CC Curved Grasper Forceps Storz Style Diameter: 5mm Working length: 36cm 90 Days Limited Warranty
AED 33321CC-R Curved Grasper Forceps w/ Ratchet Handle Storz Style Diameter: 5mm Working length: 36cm 90 Days Limited Warranty
AED A1303-R Crocodile Grasper with Ratchet Double Action Jaw Diameter: 5mm Working length: 33cm With Rotating Leur Port 90 Days Limite...
View full detailsAED H1417 Cobra Grasper, 3mm x 36cm for Medtronic TruClear Double Action Diameter: 9FR Working length: 36cm Rigid Cobra Grasper Rotating Sha...
View full detailsAED W1617 Clipper Clip Applier, Single Action For Weck Medium/Large Clips 10mm X 33cm 90 Days Limited Warranty
AED 105-845-350 Bulldog Arthro Grasper, Single/Action, With Ratchet Working length: 13cm Diameter: 3.5mm Single Action Jaw Manufactured In ...
View full detailsAED 33321C Bowel Grasper Storz Style Diameter: 5mm Working length: 36cm 90 Days Limited Warranty
AED 33321C-R Bowel Grasper w/ Ratchet Handle Storz Style Diameter: 5mm Working length: 36cm 90 Days Limited Warranty
AED PS1380 Atraumatic Grasper Forceps with Ratchet Handle 3-Piece Modular Design Double Action Jaw Diameter: 3mm Working length: 27cm ...
View full detailsAED 105-840-350 Aligator Tooth Arthro Grasper, 3.5mm With Ratchet Working length: 13cm Diameter: 3.5mm Single Action Jaw Manufactured In Ge...
View full details5mm Trocar/Cannula Leaf Valve 90 Days Limited Warranty
AED 5.5mm x 9cm Trocar-Cannula Safety Shield Trocar Includes Trap Door System 90 Days Limited Warranty
AED 5.5mm x 6cm Trocar-Cannula, Small Hasson Style for Open Laparoscopy Trumpet Valve System 90 Days Limited Warranty
AED 5.5mm x 11cm Trocar-Cannula, Trumpet Valve System 90 Days Limited Warranty
AED 101021-A 5.5mm x 6cm Trocar-Cannula Automatic Valve 90 Days Limited Warranty
AED 2790P 3-Prong Grasper Nephro Forcep 2.5mm x 36cm Irrigation Port on Handle 90 Days Limited Warranty
The AED 15mm Laparoscopic Trocar Cannula (Model AED-101015) is a professional-grade instrument designed for minimally invasive laparoscopic procedu...
View full detailsAED 11mm x 9cm Trocar-Cannula, Long Hasson Style for Open Laparoscopy Trumpet Valve System 90 Days Limited Warranty
AED 11mm x 9cm Trocar-Cannula Safety Shield Trocar Trumpet Valve System 90 Days Limited Warranty
AED 11mm x 6cm Trocar-Cannula Hasson Style for Open Laparoscopy Trumpet Valve System 90 Days Limited Warranty
The shaft diameter is fixed by the cannula, so the port plan decides the instrument set rather than the other way round. A 5mm shaft passes every 5mm and 10mm port; a 10mm shaft passes only the 10mm. That asymmetry is why most of a lap tray is 5mm and the 10mm instruments are the few that need the diameter to work - large clip appliers, specimen graspers, and the 10mm Maryland dissector where the jaw has to be substantial enough to hold a pedicle.
Length matters as much as diameter and gets less attention. A 33cm shaft is standard; 45cm exists for bariatric and high-BMI cases where the port-to-target distance defeats a 33cm instrument. Buying a 33cm-only set and then meeting a 45cm case mid-list is a common and avoidable problem.
A one-piece laparoscopic instrument is simpler and cheaper to buy. When its jaw wears or its insulation fails, the whole instrument is scrap.
A modular instrument separates into insert, outer sheath and handle. The insert is the part that wears - it takes the tissue load and the cleaning cycles - and on a modular system it is the only part replaced. Over a five-year service life the modular route usually costs less per case despite the higher purchase price, and it makes cleaning verification easier because the lumen opens up. The trade-off is assembly discipline: a modular instrument assembled wrong is a modular instrument that fails in the middle of a case.
A monopolar laparoscopic instrument carries current down a long, thin, repeatedly autoclaved shaft. The insulation on that shaft develops pinholes - from handling, from cleaning brushes, from thermal cycling - and a pinhole is invisible to the naked eye.
What makes it serious is geometry. The visible field of a laparoscope is a small cone; the shaft passes through tissue well outside it. Current leaving through a pinhole 10cm behind the jaw produces a burn nobody sees at the time, in bowel or vessel, and presents days later. This is the reason insulation testing exists as a discrete step in instrument processing rather than an optional extra, and why an insulation tester belongs alongside a monopolar lap set rather than being treated as a nice-to-have.
Bipolar instruments contain the current path between their own two jaws and remove this failure mode entirely, which is part of why they cost more.
These three cover most of what a lap tray grasps, and they are not interchangeable.
The Maryland has a fine, curved, tapered jaw. It is a dissector first and a grasper second - the curve lets it pass behind a structure and open to create a plane. Use it to develop tissue, not to hold it under load.
The Babcock has a broad, fenestrated, atraumatic jaw shaped to hold bowel without crushing it. Wide surface, low pressure. It holds; it does not dissect.
The crocodile has multiple interdigitating teeth along the jaw. It grips hard and it marks whatever it grips - right for a specimen, a suture, or a piece of mesh, wrong for anything staying in the patient.
The general rule holds here as elsewhere: the atraumatic jaw that slips on fascia and the toothed jaw that perforates bowel are the same error from opposite directions.
Are these reusable or single-use? Reusable, autoclavable instruments. The disposable items in the catalog sit under endoscopy disposables rather than here.
Can I order a modular insert on its own? Yes - inserts, sheaths and handles are listed separately where the system is modular, so a worn insert is replaced without buying a complete instrument.
Do the electrosurgical instruments include a cable? Some are listed with cable and some without; the product title states which. Check before ordering, because cable fittings are not universal across generators.
What is the difference between the 40°, 70° and 90° articulating instruments? The figure is the maximum tip deflection. Higher articulation reaches around a structure from a straight port line, at the cost of some rigidity at full deflection.
See also Laparoscopic Forceps, Needle Holders, Surgical Scissors, Hemostatic Forceps and General Surgery Instruments.
You are eligible for free shipping!